Allied Telesis 48W-B Switch User Manual


 
Installation and Safety Guide
43
4. Use only the power cord and batteries indicated in this manual. Do not
dispose of batteries in a fire. They may explode. Check with local codes for
possible special disposal instructions.
5. Remove the telephone cord from the unit prior to making changes to the
expansion port.
Save these instructions
Connection to ISDN network
Ports for the connection of other apparatus
The following interfaces normally operate at SELV (Safe Extra Low Voltage)
levels:
Asynchronous (console) ports
Ethernet ports
G703 ports
Synchronous ports
Note SELV is a secondary circuit whose voltages do not exceed a safe value
under normal operating conditions and under single fault conditions. Under
normal operating conditions the voltages do not exceed 42.4
V peak AC or
60 V DC.
TNV1
The following interfaces are Telecommunications Network Voltage (TNV1)
circuits, which operate normally within the limits of SELV:
BRI ports for connection to ISDN Basic Rate telecommunications networks
PRI ports for connection to ISDN Primary Rate telecommunications
networks
E1/T1 ports for connection to E1/T1 services
Note A TNV1 circuit is a circuit which under normal operating conditions does
not exceed the limits for SELV and on which overvoltages from
telecommunication networks are possible.