Allied Telesis 86222-27 Switch User Manual


 
Patch 86222-27 For Rapier Switches 35
Patch 86222-27 for Software Release 2.2.2
C613-10319-00 REV Z
If PPPoE AC services were not deleted in the same order they were added,
the DELETE command would return an “operation successful” message
but the service would still appear in the output of the SHOW PPP PPPOE
command. This issue has been resolved.
The CREATE CONFIG command did not include all required L3FILTER
parameters in the generated script file.
The L3 table on the Rapier G6 is now cleared when a switch port goes down
to ensure the L3 and ARP tables are consistent.
A switch port that was transmitting STP BPDUs and also mirroring its
transmit traffic to the mirror port caused a fatal error. This issue has been
resolved.
Features in 86222-06
Patch file details for Patch 86222-06 are listed in Table 21.
Patch 86222-06 includes all issues resolved and enhancements released in
previous patches for Software Release 2.2.2, and the following enhancements:
The power supply voltages of the base board PHYs on a Rapier G6 are
controlled by a PHY register value, which was incorrectly set. This issue has
been resolved.
In PIM Dense Mode, if a data stream started before PIM hello messages
were exchanged, the receiver did not get the data stream. This issue has
been resolved.
The Rapier G6 base ports sometimes experienced spurious link up or link
down events. This issue has been resolved.
PCR: 01227 Module: PPP Network affecting: No
PCR: 01229 Module: SWI Network affecting: No
PCR: 01232 Module: SWI Network affecting: No
PCR: 01234 Module: SWI Network affecting: No
Table 21: Patch file details for Patch 86222-06.
Base Software Release File
86s-222.rez
Patch Release Date
30-Aug-2001
Compressed Patch File Name
86222-06.paz
Compressed Patch File Size
226776 bytes
PCR: 01188 Module: SWI Network affecting: No
PCR: 01190 Module: PIM Network affecting: No
PCR: 01192 Module: SWI Network affecting: No