Allied Telesis AT-9924T-40 Switch User Manual


 
Page 27 | AlliedWare™ OS How To Note: EPSR
Example 6: EPSR with an iMAP
Checking the Master Node Configuration
To see a summary, use the command:
show epsr
The following diagram shows the expected output.
To see details, use the command:
show epsr=test
The following diagram shows the expected output.
--- EPSR Domain Information ---------------------------------------------------
EPSR Domain Node Type Domain Status/ Control Interface(s) (PhysicalState,
State Vlan Type, State)
--------------- --------- --------------- ------- ----------------------------
test MASTER EN/COMPLETE 1000 5.0 (UP,DNSTRM,FWDING ),
5.1 (UP,DNSTRM,BLOCKED)
-------------------------------------------------------------------------------
--- EPSR Domain Information ---------------------------------------------------
EPSR Domain Name...................... test
EPSR Domain Node Type................. Master
EPSR Domain State..................... COMPLETE
MAC Address of Master Node............ 00:00:CD:28:06:19
EPSR Domain Status.................... Enabled
Control Vlan.......................... 1000
Primary Interface..................... 5.0
Physical State of Primary Interface... UP
Primary Interface Type................ DOWNSTREAM
Primary Interface State............... FORWARDING
Secondary Interface................... 5.1
Physical State of Secondary Interface. UP
Secondary Interface Type.............. DOWNSTREAM
Secondary Interface State............. BLOCKED
Hello Timer (seconds.................. 1
Failover Timer (seconds).............. 2
RingFlap Timer (seconds).............. 0
Hello Time Remaining (seconds)........ 1
Failover Time Remaining (seconds)..... 0
RingFlap Time Remaining (seconds)..... 0
Hello Sequence........................ 526
Data Vlans............................ 2
-------------------------------------------------------------------------------