Altinex MT101-115 Network Card User Manual


 
MULTITASKER
400-0402-003
3
ABOUT YOUR MT101-114/115/117 2
MT101-114/115/117
Front Panels for the MultiTasker
12-Slot Enclosure
The MT101-114, MT101-115, and MT101-117 are
currently the three front panels available for the
MT100-108, 12-Slot MultiTasker. The front panel is
ordered separately based on the best solution for
the particular application.
Select the MT101-115 panel for applications in
which the MultiTasker needs to be controlled from
the front panel. This panel provides 36 keys which
are user-programmable. This is accomplished by
connecting a computer to the MT101-115 through
its 9-pin D-Sub RS-232 communication port and
programming the functionality of each key using
Windows
®
software provided by ALTINEX. In
applications where more power is required, the
MT101-117 should be used.
Once programmed, the keys can be used to affect
the pre-programmed switching functions and
operational functions such as press,
press-and-hold, and turning LEDs on and off. The
keys offer removable transparent faces allowing
access to removable labels for easy identification of
programmed functions. The key layout on the
MT101-115/117 resembles a typical switcher or
matrix switcher configuration with larger keys used
for input/output control and smaller keys used for
special features.
The MT101-114 panel can be used for applications
in which the MultiTasker will only be controlled with
a computer or third-party control system. Although
it does not offer any keys, it does have the main
microprocessor for the MultiTasker installed on the
inside of the panel which is required for external
RS-232 control of the MT100-108.
TECHNICAL SPECIFICATIONS 3
Specifications are subject to change.
See www.altinex.com for up-to-date information.
FEATURES/
DESCRIPTION
MT101-114/115/117
GENERAL
Compatibility
Designed for use with
MultiTasker
12-Slot Enclosures
Table 1. MT101-114/115/117 General
MECHANICAL MT101-114/115/117
T° Operating 10°C-35°C
T° Maximum 50°C
Humidity 90% non-condensing
MTBF (calc.) 65,000 hrs
Table 2. MT101-114/115/117 Mechanical
ELECTRICAL MT101-114/115/117
Power Availability MT101-114/117
Voltage Max. Current
+6V 9.0A
-6V 2.5A
+13V 1.8A
-13V 0.9A
Maximum Total Power
(Not the sum of max values.)
115W
Power Availability MT101-115
Voltage Max. Current
+6V 3.7A
-6V 1.5A
+13V 0.5A
-13V 0.5A
Maximum Total Power
(Not the sum of max values.)
45W
Table 3. MT101-114/115/117 Electrical