Altinex MT105-100 Switch User Manual


 
MULTI-TASKER
400-0131-004
9
9
The Group ID is a number representing a group
of cards defined with the [WR] command. When
using the Group ID, all cards in the group will
perform the given instruction.
Changing the position of a card will significantly
affect the commands recorded on software
definitions or third party control systems.
The Unit ID has a value from 0 to 9. Unit ID 0
should be used for single unit operation. If the
Unit ID is set to zero, each command may be
used without Ui. Use the command [SETU0],
as explained in the MT100-100 User’s Guide.
Example:
[VERC3]: For Unit ID Zero
[VERC3Ui]: For Unit ID other than Zero
[VERC3]: Equivalent to [VERC3U0]
1. [VER]
This command displays the software version
and model for the MT105-100/101 card.
Command Format: [VERCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
There is an MT105-100 in slot 4. Send the
command [VERC4] and receive the following
feedback:
[MT105-100 690-0126-014 C04]
MT105-100 = Card Model Number
690-0126-016 = Software Version
C04 = Card ID
2. [C]
This command displays the status of the card
and connections of the matrix switcher.
Command Format: [CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An MT105-100/101 card is in slot 2, Input 1 is
connected to all outputs and outputs 1, 2 and 3
are on. Send the command [C2] and receive the
following feedback:
Matrix:16X8
In01-Out1 ON
In01-Out2 ON
In01-Out3 ON
In01-Out4 OFF
In01-Out5 OFF
In01-Out6 OFF
In01-Out7 OFF
In01-Out8 OFF
NOTE: If there is no card in slot 2, sending the
command [C2] will not return any feedback.
3. [CnS]
This command saves the input to output
settings as well as the output enable status.
This configuration will be restored after the
system is reset or powered off then on.
Command Format: [CnSUi]
Cn = Card ID (n = # from 1 to max slots)
S = save configuration
Ui = Unit ID (i = # from 0 to 9)
Example:
Input 1 is connected to all 8 outputs, but only 1
through 4 are on. Send the command [C4S] for
slot 4, and receive the following feedback:
Matrix:16X8
In01-Out1 ON
In01-Out2 ON
In01-Out3 ON
In01-Out4 ON
In01-Out5 OFF
In01-Out6 OFF
In01-Out7 OFF
In01-Out8 OFF
[SAVEDC04]