Altinex MT105-111 Switch User Manual


 
MULTI-TASKER
10
10
Ix = select input x (x is # from 1 to 16)
Oy = connect to output y (y is # from 1 to 8)
Cn = card ID number (n is # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
Ui = unit ID, i is # from 0 to 9). (Refer to MT100-
100 user’s guide to set Unit ID).
S = saves command to memory
Example:
To connect input 4 to output 2 (card 2 of unit 3),
use the [I4O2C2U3] command.
[ImO*…]. This command connect input m to all
outputs.
4. [ON]
This command enables one or more outputs of
a single card or a group of cards
[ONmCnUiS]: for a single card
This command enables output “m” without
affecting any other outputs.
Default when plugged in = ALL OFF
m = Output number (m = 1 to 8)
n = Card ID number (n = 1 to 19) (1 to 8 for
MT100-101 or 1 to 4 for MT100-106)
i = Unit ID number (i = 0 to 9)
S = saves command to memory
Example:
1) [ON12C5U3]: Turns ON only output 1 and 2
of the MT105-110/(111) card located in slot
#5 of the MT100-100 Enclosure with unit
ID3.
2) [ON3C5U3]: Turns ON only output 3 of the
MT105-110/(111) card located in slot #5 of
the MT100-100 Enclosure with unit ID3.
After the [ON12C5U3] and [ON3C5U3]
commands have been executed, output 1, 2
and 3 will be ON.
3) [ONC5U3]: Turns ON all outputs of the card.
[ONmGkUiS]: for a group of cards
This command enables output "m" for each card
in group "k" of unit "i".
m = card output (m = # from 1-8)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [ON1G5U1]: Turns ON output 1 for each
card in group5 of unit 1.
2. [ONG5U1]: Turns ON all outputs for each
card in group5 of unit 1.
[ON…..P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ( [SW] ). Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded.
Command Format: [ONmCnUiP]
m = Output number (m =1 to 8)
n = card ID No. (n = a slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
P = path
Example:
If 2 cards are at slot 6 and 7 of unit 3:
To enable output 1 and 2 of card 6 and output 3
and 4 of card 7 simultaneously, use the
following commands:
[ON12C6U3P]
[ON34C7U3P]
[SW]
If "F" is included use the [ONmCnUiPF]
command or the [ONmCnUiFP] command.