Altinex MT105-111 Switch User Manual


 
MULTI-TASKER
11
11
[ON…..F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is zero.
Example:
[ON1C2U3F]: if path is not set
[ON1C2U3PF]: if path is set
5. [OFF]
This command disables one or more outputs of
a single card or a group of cards.
[OFFmCnUiS]: for a single card
This command disables output “m” without
affecting any other outputs.
m = output number (m = 1 to 8)
n = card ID No. (n = slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
I = Unit ID number (i = 0 to 9)
S = saves command to memory
[OFFCnUi]: Turns OFF all outputs of the card
Example:
1) If card 5 of unit 3 has output 1, 2 and 3 ON:
a) [OFF1C5U3]: Turns OFF output 1 while
output 2 and 3 remain ON.
b) [OFF23C5]: Turns OFF output 2 and 3.
2) If card 5 of unit 3 has output 1, 2, 3, 4, 5, 6,
7 and 8 ON:
a) [OFFC5U3]: Turns OFF all outputs, which is
equivalent to [OFF12345678C5U3].
[OFFmGkUiS]: for a group of cards
This command disables output "m" for each
card in group "k" of unit "i".
Command Format: [OFFmCnUiP]
m = card output (m = # from 1-8)
k = group number (k = # from 1-9) (1 to 8 for
MT100-101 or 1 to 4 for MT100-106)
i = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [OFF1G5U1]: Turns OFF output 1 for each
card in group5 of unit 1.
2. [OFFG5U1]: Turns OFF all outputs for each
card in group5 of unit 1.
[OFF…..P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ([SW]). Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded.
Command Format: [OFFmCnUiP]
m = output number (m =1 to 8)
n = card ID No. (n = a slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
P = path
Example:
If 2 cards are at slot 6 and 7 of unit 3:
To enable output 1 and 2 of card 6 and output 3
and 4 of card 7 simultaneously, use the
following commands:
OFF12C6U3P]
[OFF34C7U3P]
[SW]
If "F" is included use the [OFFmCnUiPF]
command or the [OFFmCnUiFP] command.
[OFF…..F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is zero.