AMCC 9550SX Computer Accessories User Manual


 
Chapter 2. CLI Syntax Reference
64 3ware Serial ATA RAID Controller CLI Guide
/c
x
/u
x
show ignoreECC
This feature only applies to 9000 series controllers.
This command shows the current setting of the ignoreECC policy for the
specified unit.
Example:
//localhost> /c0/u0 show ignoreECC
/c0/u0 Ignore ECC policy = off
/c
x
/u
x
show volumes
This feature only applies to 9000 series controllers.
This command reports the number of volumes in the specified unit. The
number of volumes will normally be “1” unless the drive capacity exceeds
2TB and auto-carving is enabled.
Example:
//localhost> /c0/u0 show volumes
/c0/u0 volume(s) = 1
/c
x
/u
x
show all
This command shows the current setting of all above attributes.
If the auto-carve policy was on at the time the unit was created and the unit is
over the carve size, multiple volumes were created and are displayed at the
end of the summary information. Similarly, if the unit was created using the
3ware BIOS utility 3BM and a size was entered in the Boot Volume Size field,
multiple volumes were created and will be displayed. (Note that a volume
created using the Boot Volume Size feature does not have to be used as a boot
volume.)
Example:
//localhost> /c0/u1 show all
/c0/u1 status = OK
/c0/u1 is not rebuilding, its current state is OK
/c0/u1 is not verifying, its current state is OK
/c0/u1 is not initializing, its current state is OK
/c0/u1 Cache State = on
/c0/u1 volume(s) = 2
/c0/u1 name = myarray
/c0/u1 serial number = C6CPR7JMF98DA8001DF0
/c0/u1 Ignore ECC policy = on
/c0/u1 Auto Verify Policy = on