Unit Object Commands
www.3ware.com 69
The quiet attribute turns off interactive mode.
/c
x
/u
x
set identify=on|off
This feature only applies to 9550SX, 9590SE, and 9650SE model controllers.
This feature requires an enclosure that uses an integrated AMCC/3ware CCU
(chassis control unit). (Check the 3ware web site for a list of chassis vendors
that support enclosure services, as they become available.) For additional
information about enclosure-related commands, see “Enclosure Object
Commands” on page 87.
This command allows you to identify a unit within an enclosure by blinking
the LEDs associated with the drive slots of the specified unit.
Example:
//localhost> /c0/u0 set identify=on
Sending Identify request for unit /c0/u0 to [on] ... Done.
/c
x
/u
x
set ignoreECC=on|off
This feature only applies to 9000 series controllers.
This command allows you to set the ignoreECC policy for a given unit.
When ignoreECC policy is set to off, if a rebuild process encounters bad
sectors on the source disk, the rebuild will fail. When ignoreECC is set to on,
such errors are ignored, and the rebuild will continue. When you use
ignoreECC, a file system check is recommended following the rebuild, to
insure data integrity.
By default, ignoreECC is off.
See Table 8, “Supported Model-Unit Types for ignoreECC,” on page 42
Table 10: Supported RAID Types for Caching
Model R0 R1 R5 R6 R10 R50 Single JBOD Spare
7K/8K Yes Yes Yes N/A Yes N/A N/A Yes No
9000
a
a. Models 9500S, 9550SX, and 9590SE
Yes Yes Yes N/A Yes Yes Yes Yes No
9650SE Yes Yes Yes Yes Yes Yes Yes Yes No