AMD M21 Switch User Manual


 
WARRANTY
Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF 24 MONTHS, after
consignment, against all defects in materials and workmanship.
This warranty does not cover failures which can be imputed to misuse, use in an application different
to that specified in the order, the result of service or modification by un-authorized persons, bad
handling or accident.
This warranty is limited to cover the repair or replacement defective parts which have not been
damaged by misuse.
This warranty is limited to the repair of the equipment and all further and eventually following
damages are not covered by this warranty.
Any consignment of equipment to our factory or distributor must be previously authorised. The
consignment should be done with the equipment well packed, clean of any liquids, grease or
hazardous materials. Tecfluid S.A. will not accept any responsibility for damage done during
transport.
Together with the equipment, a note should be enclosed indicating the failure observed, the name,
address and telephone number of the sender.
TECFLUID, S.A.
Narcís Monturiol, 33
E-08960 Sant Just Desvern
Tel. + 34 93 3724511 - Fax + 34 93 4734449
E-mail: tecfluid@tecfluid.com
Internet: www.tecfluid.com
The technical data in this document is subject to modification without notification, if the technical innovations in the product or
manufacturing processes so require.
TECHNICAL CHARACTERISTICS
The AMD is a NAMUR (DIN 19234) sensor with the following nominal characteristics:
Nominal voltage 8.2 V
Power supply internal resistance 1 k
Current with the vane into the slot < 1 mA
Current with the vane out of the slot 3 mA
Power supply limits 5 ... 25 VDC
Ambient Temperature -25 ... +100 ºC
Self inductance 160 µH
Self capacity 20 nF
Conforms with the Directive EMC 89/336/EEC
With the potentiometer we modify the current of the NAMUR amplifier. The switching point must be
between 1.2 mA and 2.1 mA. That is, with the current below 1.2 mA the output relay must have a
state and above 2.1 mA the output relay must have the other state.
Amplifier
+
+
-
-
Multimeter
mA
NAMUR
Connection
Potentiometer 20 k