American Standard 7440.101 Laptop Docking Station User Manual


 
M965227
12
11
4
SERVICE
Turn off hot and cold water
supplies before beginning.
CAUTION
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
10
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
2
5
2
1
“P” TRAP
WASTE
OUTLET
OFF
ON
COLD
HOT
3
2
2.5mm HEX KEY
5
6
7
1
4
To remove or replace cartidge: Fig. A.
Turn valve to OFF position.
Remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RING (7) for
debris and clean if necessary.
Clean MANIFOLD (1) and rinse clean.
Reinstall CARTRIDGE (6) and O-RING (7) onto
MANIFLOD (1).
Reinstall CARTRIDGE NUT (5), CAP (4) and
HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from
OFF to ON and HOT to COLD position. Do not
force handles.
3