Ask Proxima C180 UG Projector User Manual


 
38
Replacing the projection lamp
The lamp hour timer in the About menu counts the number of hours the
lamp has been in use. When the lamp timer reaches the estimated total lamp
life, the LED on the projector’s keypad blinks red (indicating a lamp error,
see page 42) and a dialog box appears each time the projector is turned on.
You can order new lamp modules from your dealer. See “Accessories” on
page 41 for information.
1 Turn off the projector and unplug the power cable.
2 Wait 60 minutes to allow the projector to cool thoroughly.
3 Turn the projector upside down and remove the lamp door by loosening
the captive screw and then prying the lamp door out.
4 Remove the two screws on the lamp module.
WARNINGS:
To avoid burns, allow the projector to cool for at least 60 minutes before
you replace the lamp.
Unplug the power cord before replacing the lamp.
Do not drop the lamp module. The glass may shatter and cause injury.
Do not touch the glass lamp screen. Fingerprints can obscure projection
sharpness.
About menu
computer 2
network
monitor out
audioout
audioin
L
audio in
serial control
computer in
computer 1
video 2
video in
R
S-video 1
turn off and unplug
the projector
wait 60 minutes
loosen the screw on lamp door
pry the lamp door off
remove the screws on lamp module