Asus Crosshair V Formula- Computer Hardware User Manual


 
3-34
Chapter 3: BIOS setup
Chapter 3
Chassis Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the CPU temperature.
The values range from 40ºC to 90ºC.
Chassis Lower Temperature [40]
Displays the lower limit of the chassis temperature.
Chassis Fan Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle.
The values range from 60% to 100%. When the chassis temperature
reaches the upper limit, the chassis fan will operate at the maximum duty
cycle.
Chassis Fan Min. Duty Cycle(%) [60]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle.
The values range from 60% to 100%. When the chassis temperature is
under 40ºC, the chassis fan will operate at the minimum duty cycle.
OPTFAN 1-3 Control [Disabled]
Allows you to disable or set the optional fans’ warning speeds.
Conguration options: [Disabled] [Duty Mode] [User Mode]
OPTFAN 1-3 Duty
Allows you to set the optional fans’ speed duty percentagea.
Conguration options: [40%] [50%] [60%] [70%] [80%] [90%]
User Mode
Allows you to set the optional fan’s speed temperature.
OPT1-3 Low Speed Temp [25ºC]
Allows you to set the optional fans’ low speed temperature.
Conguration options: [25ºC] [30ºC] [35ºC] [40ºC]
OPT1-3 Full Speed Temp [60ºC]
Allows you to set the optional fans’ low speed temperature.
Conguration options: [60ºC] [70ºC] [80ºC] [90ºC]