OnePower Line Interactive UPS (EN)
A03-P701 / A03-P551 Pag. 22
normally, but the
site wiring fault
indicator is lit.
as missing ground or hot to
neutral wire reversal.
order to correct the building
wiring.
A.1.2 Upsilon2000
Situation
Solution
How to install
the
UPSilon2000.
Once started the UPS you can connect it to PC through USB
cable. At this time the SO detects and installs automatically all
drivers. Now you can install UPSSILN2000 on the PC.
PC doesn’t
find the UPS.
1. Check if the cable is properly connected
2. Use the original cable
3. Launch Upsilon2000, then click on INSTALLATION and
check that TYPE OF COMMUNICATION is (USB).
A.1.3 Battery and Fuse
Situation
Solution
Backup time
The battery backup time (sometime called battery reserve
time or battery autonomy) is the length of time the battery will
supply power to the load during a power failure. You can
check on the Appendix Backup Time.
Wich type of
battery does
UPS use?
12VDC- 7A/h.
How often do I
have to
change
battery?
Atlantis recommends to replace the batteries once a year.
Where can I
find batteries?
1. please contact Your reseller.
2. please contact directly Atlantis Land.
How can I
check the
Fuse?
Check the fuse to be sure it is not blown or damaged. Also,
make sure the fuse makes good contact and is not loose in
the fuse holder. Ensure that you are using the correct size
fuse. If you replace the fuse and the UPS again blows the
fuse, please contact Atlantis Land.
Fuse
specification.
[6.5A, 250Vac on A03-P701], [4A, 250Vac on A03-P551] You
can found on the rear panel (AC Fuse holder) a fuse.