ATO CMM 900-3W Network Card User Manual


 
Page 14 of 14
information.
Note: MIN, ESN, SID information are stored in
the Non-volatile memory of the cell-modem
and do not need to be entered on every Power-
up.
To exit Test mode, enter AT+MODE=02<CR>
ATQ1<CR> Unit does not respond with OK or non-verbose
messages. This is ideal for in situations where the
Data Link is connected to a “non-intelligent” host.
This mode is also called Quiet Mode.
ATQ1&W&W1 Q1 instruction stored in non-volatile memory.
AT&V<CR> Displays settings of the cell modem
ATI3<CR> Displays Software Revision #
ATH0 Modem disconnects and initializes.
ATV0 Unit responds in terse mode. Results code is
displayed as digits
ATV0&W&W1 Above command stored in non-volatile memory.
On power-up, the modem will be in terse mode.
ATV1 Unit responds in verbose mode. Results codes are
displayed as messages.
ATV1&W&W1 Above command stored in non-volatile memory. On
power-up, the modem will be in verbose mode.
ATS0 Default is 0. If 0, then the unit will not answer
incoming call. Please use ATS0=1&W&W1 to have
the unit answer incoming calls.
+++ Escape Sequence. The Radio will respond with OK
on detection of valid escape sequence.
When the modem is on-line state, it is possible to
break the data transmission/reception.
This is achieved by sending a sequence of three
ASCII characters. For ease of use, the default
character is +.