ATTO Technology 2390C/R/D Network Router User Manual


 
viii
EmailNotifyAddress
Configures notification addresses. Index is a number 1-5.
Full Email address
is a fully qualified Internet Email
address, not more than 128 characters long. Warning
level can be
All, Warning
,
Critica
l or
None
.
None
means no Emails are sent;
Critical
means only critical
severity events sends an Email;
Warning
means only
warnings and critical events send Email, and
All
means
all warnings and critical events warrant an Email.
set EmailNotifyAddress [index] [full email address]
[warning level]
get EmailNotifyAddress <index | all>
EmailPassword
Configures the password used to authenticate the login to
the SMTP Email server. The password must not be more
than 64 characters. A password is not required if the
Email server does not require authentication.
set EmailPassword
Requires a SaveConfiguration command
EmailServerAddress
Configures the address of the server the FibreBridge
must contact in order to send out Email notifications.
set EmailServerAddress [IP address]
Requires a SaveConfiguration command
get EmailServerAddress
EmailUsername
Configures the user name used to authenticate the login
to the SMTP Email server. The user name must not be
more than 128 characters. A user name is not required if
the Email server does not require authentication.
set EmailUsername
Requires a SaveConfiguration command
get EmailUsername
EthernetSpeed
Sets/displays the current speed of the Ethernet
connection. Choices are 10, 100, and Auto.
Default: auto
set EthernetSpeed [mp1] [ 10 | 100 | Auto ]
Requires a SaveConfiguration Restart command
get EthernetSpeed [mp1]
If auto enabled, value in parentheses indicates current
speed
EventLog
Regulates event logging. When enabled, records various
system events to the event log.
Default: enabled
set EventLog [enabled | disabled]
get EventLog
EventLogFilter
Filters data from specific unit subsystems and levels when
event logging is enabled. The specific entries supported
are platform-dependent. For set commands, the final
parameter indicates whether or not events from the
specified subsystem and level are displayed.
Default: all all all
set EventLogFilter [subsystem | all] [event level | all] [all |
none]
get EventLogFilter [subsystem | all ] [level | all]
Exit
Ends the current Ethernet Telnet CLI session; it has no
effect if used during a serial CLI session.
Exit
FCConnMode
Controls/reports the connection the FibreBridge uses
when communication across a FC network, either to an
arbitrated loop (FC-AL) when you select
loop
, or point-
to-point when you choose
ptp
. If you choose
loop-ptp
or
ptp-loop
, the FibreBridge tries to use the first parameter
first, but uses the second if it cannot use the first.
Default: loop
set FCConnMode [fp | all] [loop | ptp | loop-ptp | ptp-loop]
Requires a SaveConfiguration Restart command
get FCConnMode [fp | all]
FCDataRate
Specifies the rate the FibreBridge uses, 1 Gb/sec., 2
Gb/sec. 4 Gb/sec. or auto negotiate.
Default: auto
set FCDataRate [fp | all] [1Gb | 2Gb | 4Gb | auto]
Requires a SaveConfiguration Restart command
get FCDataRate [fp | all]