Avaya M770 Switch User Manual


 
Avaya M770 User’s Guide 1
Chapter 1
Quick Start
To start using the Avaya M770, plug in at least one Power Supply unit and at least
one M-SPV/M-SPX (Avaya M770 supervisor) module into the rear of the chassis,
and switch the Power Supply ON. The Avaya M770 requires at least one 500W PSU
(M-PS500) and one M-SPV/M-SPX module. To use it as is, simply connect the PSU
to a suitable power source.
Note: The Cable Manager panel is packed separately in order to protect the cable
manager. Please refer to Installing the Cable Manager below for details.
If you are installing the Avaya M770 in a rack, you can adjust the depth by fixing the
enclosed Rack Mount plates (refer to Installing the Depth-Adjusting Plates below).
You must install the plates before inserting modules since the installation requires
work inside the hub.
Installing the Cable Manager
The Avaya M770 hub is packaged with a blank panel affixed to the base of the front
of the hub. You can pull off the blank panel (unclip it) and replace it with the Cable
Manager (packaged separately from the hub) if required. Perform the following
steps:
1 Remove the blank panel by unclipping it.
2 Carefully align one side of the Cable Manager and clip it into position.
3 Bend the Cable Manager outwards slightly and clip the other end into the hub.
4 Press the Cable Manager along its length onto the hub to fasten the remaining
clips.
To remove the Cable Manager gently unclip the side fasteners first from behind
using a screwdriver and then pull it off the hub.
Installing the Depth-Adjusting Plates
If you wish to install the Avaya M770 in a rack which is shallower than the hub itself
you can add two plates on the side panels to reduce the effective rack-mounting
depth.