Baracoda 2 Barcode Reader User Manual


 
BaracodaPencil 2 – Communication Protocol v1.3 - 37 -
Data Capture
for Workforce
in Motion
Command
Set page scan timeout
Header
0x24
Length
00 04
Payload
[Page Interval (MSB) | Page Interval (LSB) | Page Window (MSB) |
Page Window (LSB)]
(default 0x320, 0xb0)
Response
0x24 00 01 01 if done
0x24 00 01 00 if not
Remark
Page Scan TimeOuts are used by the Module to answer to Connect
Inquiries. So, if you set both values to 0, the Module will not be
Connectable.
Command
Get page scan timeout
Header
0x25
Length
00 00
Payload
Response
0x25 00 04 [P
age Interval (MSB) | Page Interval (LSB) | Page
Window (MSB) | Page Window (LSB)]
Remark
Page Scan Interval and Page Scan Window are in number of
Bluetooth slots) (1 slot = 0.625 ms)
Typical values are:
Full power:
Inquiry Interval = 0x400
Inquiry Window = 0x200
Page Scan Interval = 0x400
PageScan Window = 0x200
Low power:
Inquiry Interval = 0x320
Inquiry Window = 0x80
Page Scan Interval = 0x320
PageScan Window = 0x80
Here is how these values change the consumption of the Module:
Page Scan and Inquiry Scan Interval
Inquiry Sc
an
Window
Page Scan
Window