Barco R9000901 Projector User Manual


 
AC power connection
6-2 5975996 BARCOGRAPHICS 808s 241197
AC Power check
Check the power voltage which is determined by the ART. NR. (Article
number) included in the label pasted on the backside of the projector.
Projectors with the ART. NR. R9000901 and R9000902 must be
connected to a 230 VAC power source.
Projectors with the ART. NR. R9000908 and R9000907 must be
connected to a 120 VAC power source.
If the indicated voltage is different from that of the wall outlet, call a
qualified technician for power adaptation of the projector.
AC Input power (mains) voltage adaptation
Attention !
The BARCOGRAPHICS 808s - R9000901 and R9000902 leave the
factory to operate on a mains (power) input of 230 Vac.
The BARCOGRAPHICS 808s - R9000908 and R9000907 leave the
factory to operate on a mains (power) input of 120 Vac.
Adaptation of the power input of the projector between 230 Vac and
120Vac or vice versa is possible.
Follow the procedure as described below to adapt the voltage :
WARNING: turn off the projector and be sure the AC Power
Cord is unplugged before starting the procedure !
Open the top cover (see 'Access to controls' on p.4-1).
Unscrew the retaining screws of the AC power input board and
remove this board.
ART.NR.:RXXXXXXX
SER.NR.:RXXXXXXX
Power selector plug
Fuses
AC Power
input board
Power selector on 230V
Power selector on 120V
230V
120V
1
2
3
Pull out the 'Power selector plug' (Photo 2) and reinsert it as
illustrated in Photo 3, depending on the AC power of the wall outlet
in the room.
Pull out the fuses and place the correct fuses in their sockets. See
the table below for the correct type of fuses.
Reinsert the power input board and secure it with the retaining
screws.
Fuses
Warning !
For continued protection against fire hazard :
Replace with the same type of fuse.
Refer replacement to qualified service personnel.
AC power Fuses Order Number
230 Vac T6.3A/250V (2x) R314145
120 Vac T10A/250V (2x) R314154