Bay Technical Associates DS72 Network Card User Manual


 
DS72 HOST MODULE OWNER’S MANUAL
INTRODUCTION TO THE DS72 HOST MODULE
1
INTRODUCTION TO THE DS72 NETWORK INTERFACE
MODULE
The DS72 network interface module is a primary user interface for use with the BayTech DS-Series and
DS-RPC units. The DS72 allows network users operating on a device using a TCP/IP stack with an
ethernet connection, to access the main DS units, serial I/O modules, and (in the case of the DS-RPC)
remote power switches. It also allows remote access via external modem to the serial port. This makes the
DS72 an extremely versatile module, covering most applications.
PROGRAMMABLE FEATURES OF THE DS72
Highlighted features indicate items most often programmed
FEATURE DESCRIPTION ACTION PAGE
NO.
DS72
N
ETWORK
I
NTERFACE
M
ODULE
Serial Port
Configuration
Sets serial port speed of the DS72 Default = 9600, 8, 1, N,
Xon/Xoff Disabled
Enter baud rate, data bits,
stop bits, parity, and
Xon/Xoff
11
Port Device
Name
Uniquely identifies the port (or device connected to the port).
Default = Host EIA-232
Enter the device name 12
Port Select Code ASCII character string used to select a port or module.
Default = $BT
Enter Port Select Code 13
Attention
Character
A character sent in sequence five times to invoke the main
menu. Default = ;
Enter Attention Character 14
Disconnect Time
Guard
Provides reliable binary data transmission. Default =
Disabled
Enable/Disable
Disconnect Time Guard
14
Port ID Echo Echoes the module number and port number when you
connect to the port.
Default = Disabled
Enable/Disable Connect
Port ID Echo
14
Header Unit information that appears upon login
Default = DS72
Enable/Disable Header 15
Password Password protection for telnet and EIA-232 connections.
Default = Disabled
Enable/ Disable, and
Program Password
16
Menu Provides a menu interface for device selection, and
configuration.
Default = Enabled
Enable/Disable Menu 16
Auto Connect
Port
Allows automatic connection to a specified port upon Telnet
or EIA-232 connection.
Default = Disabled
Enable,/Disable, and
Program Auto Connect
Port.
17
IP Address IP Address for the DS72 to access the network.
Default = 0.0.0.0
Enter the IP Address in
dotted decimal format
0.0.0.0
18
Subnet Mask Consists of four bytes, each byte ranging from 0 to 255.
Default = 0.0.0.0
Enter the Subnet Mask in
dotted decimal format
0.0.0.0
19
Gateway Consists of four bytes, each byte ranging from 0 to 255.
Default = 0.0.0.0
Enter the Gateway in
dotted decimal format.
0.0.0.0
19