Bay Technical Associates Fiber Media Adapter Network Card User Manual


 
893-863-A 3
LEDs
The BayStack 10BASE-FL RDN Media Adapter provides LEDs
to indicate remote signaling and redundant link status. These
LEDs are used in combination with the BayStack 10BASE-T
Hub “Media Adapter” LED to indicate the status of the active
and standby link.
Table 1 describes the redundant 10BASE-FL media adapter
LEDs.
Table 1. 10BASE-FL RDN Media Adapter LEDs
Label Color Meaning
Rem Green Fiber port is connected to a remote port that uses
remote signaling, and that port is not sending a
remote fault signal; both Tx and Rx connections
are good.
Amber Fiber port is connected to a remote port that uses
remote signaling, but the Tx link to the remote Rx
connector detects a remote fault.
Off Fiber port is not connected to another port that is
capable of remote signaling.
Rdn Green Port is in redundant mode and detects no fault.
Amber Port is in redundant mode, but this redundant port
connection has failed.
Off Port is not in redundant mode.