B&B Electronics EIR505-XX Switch User Manual


 
42
Manual Documentation Number: EIR505-xx_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
¾ COS only: The port will follow the COS priority assigned
¾ TOS only: The port will follow the TOS priority assigned
¾ COS first: The port will follow COS priority first, and then another
priority rule
¾ TOS first: The port will follow TOS priority first, and then another
priority rule
COS priority: Set the COS priority level 0~7
TOS priority: The system provides 0 to 63 TOS priority levels. Each
level has 4 types of priority – high, mid, low, and lowest. The default
value is “Lowest”. When the IP packet is received, the system will check
the TOS value.
[NOTE] QoS and Rate control cannot be used simultaneously.