Chapter 10 Configuring the NetServer
74
• Include SCSI_A Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this
setting selectively includes or excludes SCSI port A from the
HP NetRAID subsystem.
• Include SCSI_B Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this
setting selectively includes or excludes SCSI port B from the
HP NetRAID subsystem.
NOTE If you enable HP NetRAID for just one SCSI channel, that
becomes the integrated HP NetRAID Channel 0. If you enable
both SCSI channels, SCSI A becomes Channel 0, and SCSI B
becomes Channel 1. For single-channel RAID operation, HP
recommends SCSI A.
5. If necessary, you can use the Setup utility to change other settings,
such as IRQs or MP specification settings, or boot order.
6. Press the F10 function key to save and exit.
7. In the Setup Configuration dialog box, press the Enter key to answer
"yes" to the question: "Save configuration and exit now?" The
NetServer will reboot.
For complete information on HP NetRAID, see the Integrated HP NetRAID
Configuration Guide.
Symbios Configuration Utility
If you need to verify or modify SCSI host adapter settings, or if you need to low-
level format SCSI disks or verify SCSI disk media, run the Symbios
Configuration utility, as follows:
Turn on or reboot your system.
During system start-up or reset, when the message
Press <Ctrl> <C> to start Symbios Configuration
Utility
appears, press the CTRL and C keys at the same time.