Mode
: The SHDSL device can function as a CPE (Customer Premises Equipment) or CO. Select CPE
mode when the BiPAC 8501 is connecting to your ISP.
Annex Type: It is the DSL operating mode standard. Select Annex A or Annex B to support up to 5.7Mbps
SHDSL.bis function. Select other annex such as Annex B_ANFP / Annex A_B_ANFP, you may consult
with your ISP first.
Bit Rate Mode: The mode selections are Adaptive and Fixed. Selecting the Adaptive mode, the best
connection rate will be automatically negotiated with the CO / ISP. Selecting the Fixed mode, the
connection rate will be fixed to the specific fixed bit rate selected with the CO / ISP.
Fixed Bit Rate: Specify the fix transfer rate when Fixed Mode is selected. Specify the maximum
transfer rate when Adaptive Mode is selected. Bit Rate range is from 72kbps ~ 5704kbps.
Activate Line: Line active true is set by default. Select false to disable and true to enable SHDSL
SHDSL connection
Note: Once Active Line is selected as false, you must enable the Active Line to true again and click Apply button to
reactivate SHDSL connection.
DSP FirmwareVersion: Display the SHDSL line code firmware version.
Connected: Display current SHDSL line sync status.
State: Display current SHDSL line status.
Bit Rate: Display SHDSL line synch speed rate.
Click Apply button to apply your changes.