Black Box ACR1002A Switch User Manual


 
Chapter 3: Installation
724-746-5500 | blackbox.com
Page 21
3.2.5 Local Power In
Each ServSwitch Agility unit is supplied with an appropriate power supply - Note: Agility Dual units are supplied with a slightly
higher capacity supply (please see section 3.2.5.1 below).
1 Attach the output lead from the supplied power adapter to the 5V socket on the rear panel of the unit. See Figure 3-10.
INDOOR
USE ONLY
OPT
1
5V
2.5A
1
Note: Ensure that
Option switches
1 and 2 are both
in the ‘off’ (up)
position to enable
normal operation
of the unit.
Figure 3-10. Connect the power supply to the rear panel power socket.
2 Connect the IEC connector of the supplied country-specific power lead to the socket of the power adapter.
3 Connect the power cord to a nearby power supply socket. When all other connections have been made, switch on the power
supply unit.
Note: Both the unit and its power supply generate heat when in operation and will become warm to the touch. Do not enclose
them or place them in locations where air cannot circulate to cool the equipment. Do not operate the equipment in ambient tem-
peratures exceeding 40
o
C. Do not place the products in contact with equipment whose surface temperature exceeds 40
o
C.
3.2.5.1 Power supply identification
Due to the increased power requirements of the ServSwitch Agility Dual units, these models are supplied with larger capacity
(20W) power adapters. The standard 12.5W and higher power 20W adapters use identical housings, so within installations where
both types are used, you need to double check the underside labels to differentiate the two types:
Power lead from
power supply
No damage will be caused if the 12.5W adapter (p/n
PS649-R3) and the 20W adapter (p/n PS650) are used
in place of each other on either of the Agility or Agility
Dual units. However, correct operation of Agility Dual
units can only be guaranteed if a 20W power adapter is
used. Always ensure that only the supplied (or
authorized replacement) 5-volt power supplies are used
to power the units.
Model:
SA06-xxxxx-V
Input:
100-240V
Output:
5V
2.5A (12.5W Max.)
Model:SA06-xxxxx-V
Input: 100-240V
Output:5V
Model:SA06-xxxxx-V
Input: 100-240V
Output:5V
2.5A (12.5W Max.) 4A (20W Max.)
12.5W m odel
(for Agility)
20W m odel
(for Agility Dual)
Figure 3-11. How to differentiate the power supplies
for the ServSwitch Agility and Agility Dual