Black Box LB9017A-R3 Switch User Manual


 
Express Ethernet Switch: LB9017A-R3
8
Flashing
T
ransmittin
g
or receivin
g
data
ACT stands for ACTIVITY
ACT
Off Neither transmitting nor
receiving data
On A valid network connection
LNK stands for LINK
Flashing
T
ransmittin
g
or receivin
g
data
ACT stands for ACTIVITY
LNK/ACT
Off Neither connection nor
activity
On A valid 100Mbps connection
Port LED
SPEED
Off
A valid 10Mbps connection
On A valid network connection
LNK stands for LINK
LNK
Off No connection
Flashing
T
ransmittin
g
or receivin
g
data
ACT stands for ACTIVITY
100FX
Port
LED
ACT
Off Neither transmitting nor
receiving data
Installation
Selecting a Site for the Equipment
As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
- The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 50 degrees Celsius).
- The relative humidity should be less than 90 percent, non-condensing.
- Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M)
field strength.
- Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes on each side of the switch or
on the rear of the equipment.
- The power outlet should be within 6 feet ( 1.8 meters ) of the switch.