Black Box Cable Length Meter Computer Accessories User Manual


 
724-746-5500 | blackbox.com Page 19
Chapter 4: Using the Cable Length Meter
4. Warble tones, low tone for 365 ms, followed by 65 ms of high tone.
Figure 4-6. Tone Mode screen.
4.5 Calibrating the Test Lead
1. Hold down the LEAD CAL key until the unit displays CAL. The unit will display
CAL for a few seconds then display Shrt Lead.
2. Short the leads as illustrated Figure 4-7. Once connected properly to the bus wire,
press the LEAD CAL key again. The unit will beep and display OPEN LEAD.
3. Disconnect the leads from the short. With the test leads open, press the LEAD
CAL button. The unit will be beep and go into its normal operation mode. This
completes the calibration procedure. This procedure must be done correctly for
good measuring results.