Black Box LB303A Network Hardware User Manual


 
Hardened VDSL Ethernet Extender
Connecting to Power
Redundant DC Terminal Block Power Inputs or 12VDC DC Jack:
12VDC DC Jack
Step 1: Connect the supplied AC to DC power adapter to the receptacle
on the topside of the Hardened VDSL Ethernet Extender.
Step 2: Connect the power cord to the AC to DC power adapter and
attach the plug into a standard AC outlet with the appropriate AC
voltage.
Redundant DC Terminal Block Power Inputs
There are two pairs of power inputs can be used to power up this device. You only need
to have one power input connected to run the Hardened VDSL Ethernet Extender.
Step 1: Connect the DC power cord to the plug-able terminal block on
the Hardened VDSL Ethernet Extender, and then plug it into a standard
DC outlet.
Step 2: Disconnect the power cord if you want to shut down the
Hardened VDSL Ethernet Extender.
Power Input Assignment
Power1 12VDC DC Jack
Power2
12-30VDC
Terminal Block
Power Ground
Power3
12-30VDC
Power Ground
Earth Ground
DIP Switch Assignment
Loc The device operates in local mode
Rmt The device operates in remote mode
11