INTEGRUS | Installation and User Instructions | Connecting to an Integrus transmitter en | 10
Bosch Security Systems | 2005-04 | 9922 141 70164en
3.1.2 Recording the audio channels
To record the audio channels, a connection box can be
inserted between the interpreters desks LBB 3222/04
and the Integrus audio input and interpreters module
LBB 3422/20. Such a connection box should be local-
ly made. See figure 3.3 for the wiring.
LBB 3422/20
1
14
4
18
2
16
5
17
7
19
8
22
6
20
11
23
9
21
3
15
24
25
12
13
10
Audio 1 input
Audio 2 input
Audio 3 input
Audio 4 input
Audio 5 input
Audio 6 input
Audio 7 input
Audio 8 input
Audio Comm
Audio AF
Supply (+12V)
1
14
4
18
2
16
5
17
7
19
8
22
6
20
11
23
9
21
3
15
24
25
12
13
10
OR Floor Channel
LBB 3222/04
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Busy in
Comm.
OR2 Auto Relay
Supply (+27V)
Ground
RECORDING EQUIPMENT
Earth
Supply
(-
12V)
Earth
14 x
Floor
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Figure 3.3 Connection box for recording audio and language channels