Brady 200M-e Printer User Manual


 
100 Bradyprinter 200M-e and 200M-e 300 User’s Guide
RS-232 Interconnections Using a DB25 Cable
In order to connect the printer’s RS-232 DB9 interface to a DB25
connector, an interface adapter is required. A generic DB25 adapter may
also be used, however the +5VDC signal source would not be passed
through. Figure 39 illustrates the connections required for the DB9 to
DB25 interface.
NOTE: The cable used to connect the printer to a computer must
be a null modem (crossover) cable. If you want to connect the
printer to any other DTE devices, you must also use a null modem
cable.
Figure 39