Brother HL- 2400Ce Printer User Manual


 
2001/10/02
CHAPTER 4 HP-GL/2 - 28
90 LPRINT "FT4,100,45;RA4250,4750;"
100 LPRINT CHR$(27); "%0A";
110 LPRINT CHR$(27); "E";
120 END
<Sample 34>
RR - Fill rectangle relative
RR X, Y[;]
X ; X coordinate of opposite corner for the rectangle
Y ; Y coordinate of opposite corner for the rectangle
Coordinates relative to the current position in current units.
Fill the rectangle formed by the current position and the opposite corner specified by X and Y.
After plotting the cursor returns to its point of origin.
Plotting is performed whether the pen is up or down.
10 ' - Fill Relative Rectangle -
20 WIDTH "LPT1:", 255
30 LPRINT CHR$(27); "E";
40 LPRINT CHR$(27); "%0B";
50 LPRINT "IN;SP1;PA5000,4000;"
60 LPRINT "FT1;RR750,750;"
70 LPRINT "PR750,0;"
80 LPRINT "FT3,100;RR750,750;"
90 LPRINT "PR0,750;"
100 LPRINT "FT2;RR750,750;"
110 LPRINT "FT4,100,45;RR-750,750;"
120 LPRINT CHR$(27); "%0A";
130 LPRINT CHR$(27); "E";
140 END
<Sample 35>
WG - Fill wedge
WG r,q1,qc(,qd)[;]
r ; Radius in current units
q1 ; Start point angle
qc ; Arc angle
qd ; Chord angle
Fill in a wedge centred on the current position with radius r, start point angle q1, arc angle qc and chord angle
qd.
After plotting, the cursor returns to its point of origin.
Plotting is performed whether the pen is up or down.
You should use this command with the type "isotropic". Anisotropic type may make the wedge stretch.
r specifies the radius of circle. A positive value places the 0° reference point onto the positive x-
axis and the negative value places it onto the negative x-axis.
The value for q1 is a clamped real number.
q1 specifies the wedge starting point related to the 0° reference point.
When q1 is positive, the positive direction of the X axis relative to the current position is set at 0 degrees and
the start point is sought in the counterclockwise direction. The opposite occurs when q1 is negative: the
negative X axis is set at 0 degrees and the start point is sought by going clockwise.
qc specifies the angle of the wedge.
The value for qc is a clamped real number.
Plotting proceeds counterclockwise when qc is positive and clockwise when negative.
The value for qd is a clamped real number.
When qd is not specified, the chord angle is the default value ( 5 degrees ).