Variables Description Sample Value Range
DUPLEX Duplex mode ON, OFF
BINDING Returns the setting of binding edge
selection for duplex printing.
LONGEDGE, SHORTEDGE
FIRSTPRINT First print mode. This makes the
first print speed faster by starting
the polygon mirror motor at Power
On. Setting to MIDDLE is effective
only for the first page after Power
ON. Setting to HIGH makes the
scanner motor rotate continuously.
NORMAL, MIDDLE, HIGH
DENSITY Returns the printing density level
setting from 1 to 15. The default
value is 8.
1 (lighter) to 15 (darker)
LANG Returns the language for control
panel and status readback
information.
ENGLISH, FRENCH, GERMAN,
DUTCH, SPANISH, ITALIAN,
FINNISH, NORWEGIAN,
PORTUGUESE, DANISH
CPLOCK Returns the lock status of the
control panel. If OFF, the control
panel is unlocked. If ON, the control
panel is locked.
OFF, ON
PASSWORD Password for panel lock to write to
the NVRAM with the
DEFAULT/INITIALIZE command.
0 to65535
ECONOMODE Toner Saving Mode OFF, ON
ECONOLEVEL Level for Toner saving mode. If set
to 1, approx. 50 % toner is saved. If
set to 2, approx. 25% toner is saved.
1, 2
MPTRAY MP Tray Priority For AUTO feeder
selection mode.
CASSETTE, FIRST
AUTOSLEEP Power Save Mode ON, OFF
TIMEOUTSLEEP Timeout for Power Save mode. The
printer goes into the power save
mode after this time-out period
(minutes).
1 to 99
MEDIATYPE Media Type. The temperature of
fixing unit is adjusted depending on
this setting.
REGULAR, THICK,
TRANSPARENCY
HUMIDITY Depending on this setting, the fixing
voltage of the printer is adjusted.
LOW, HIGH
COLLATE * Sets collated printing. ON, OFF
HOLD * Specifies whether the received data
is stored in the hard disk or printed.
PROOF, STORE
HOLDTYPE * Specifies the document type of the
received data which has been stored
in the optional hard disk. If
PRIVATE is selected, a password is
required for the data to be printed or
deleted.
PUBLIC, PRIVATE
HOLDKEY * Specifies the password when the
document type is set to PRIVATE.
0 to 9 (4 digits to be selected)
TIMESETYEAR * Clock: year setting 1998 to 2039
TIMESETMONTH
*
Clock: month setting 1 to 12
TIMESETDAY * Clock: date setting 1 to 31
TIMESETHOUR * Clock: hour setting 0 to 23