Cables to Go CDM-570L Network Router User Manual


 
Vipersat Configuration
3-18 Vipersat CDM-570/570L User Guide
The Remote Policies screen for an Entry Channel Hub type allows the SCPC
data rates and switch types to be specified for when a Remote will switch and
the desired starting point for communications.
Figure 3-21
Entry Channel Switch Rates screen
Entering the Remote number at the command prompt in figure 3-21 allows the
SCPC Data Rate and the Switch Type for that Remote to be set, as shown in
figure 3-22. Switch type 0 corresponds to Load Switching; switch types 64
through 255 are user-defined, and must match VMS policies.
Figure 3-22
Remote SCPC Data Rate and Switch Type prompt
The Global SCPC Rate command can be used to set the data rate for all or a
majority of the Remotes. This allows the rate to be entered just once instead of
entering the rate for each remote individually. Enter G at the command prompt.
Figure 3-23
Global SCPC Data Rate prompt
Similarly, the Global Switch Type command can be used to set the switch type
for all or a majority of the Remotes. Enter H at the command prompt.