Cabletron Systems 36 Network Card User Manual


 
FOMIM User’s Guide 2-1
CHAPTER 2
NETWORK REQUIREMENTS AND
INSTALLATION
This chapter begins with network design guidelines in Section 2.1,
Network Cable Requirements
, that must be met before installing the
module in a network. It then provides instructions for installing the
Cabletron Systems Fiber Optic Media Interface Module into the MMAC
family of modular hubs.
2.1 NETWORK CABLE REQUIREMENTS
When connecting fiber optic segments to the FOMIM, you must follow
the network guidelines listed below. Failure to do so may result in
unsatisfactory network performance.
2.1.1 Fiber Optic Network Design Guidelines
The fiber optic link segment should consist of 8/125 – 12/125
µ
m
single mode fiber optic cabling. You can also use 62.5/125
µ
m
multimode cable with the FOMIM. However, optical loss will be
greater with multimode cable and distances will be limited to 2 km.
The fiber optic cable must be tested with a fiber optic attenuation test
set that is adjusted for a 1300 nm wave length. This test verifies that
the signal loss in a cable is within an acceptable level of 9.0 dB or less
for any given single mode fiber optic link.
When determining the maximum fiber optic cable length, the fiber
optic budget (total loss of 9.0 dB or less between stations) and total
network propagation delay should be calculated and considered before
fiber runs are incorporated in any network.
Fiber optic budget is the combination of the optical loss due to the
fiber optic cable, in-line splices, and fiber optic connectors (the loss
for each splice and connector is typically 1 dB or less).