Carrier Access 3200 Network Card User Manual


 
12 Adit 3200 - Release 1.6
Quick Start
Interface Connectors
Interface Connectors
The following are the Adit 3200 interface connectors:
Front of Adit
z (1) DS1 WAN port (RJ-48C). Note: E1 will be in a future release.
z (1) 10/100Base-T WAN port (RJ-45)
z (4) 10/100Base-T switched LAN ports (RJ-45)
Back of Adit
z RS-232 craft port connector for local management
z Power input connector
z Ground connector
Grounding the Unit
WARNING! THE ADIT 3200 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE
PROTECTION OF USERS AND SERVICE PERSONNEL.
Chassis ground is located on the back of the unit.
To ground the unit:
1. Connect a minimum 14 AWG ground
wire with a #8 ring tongue terminal (not
included) to the chassis ground on the
back of the unit. Secure with the 8-32
screw and lock washer provided.
2. Connect the opposite end of the ground
wire to a suitable earth grounding point
such as a building grounding electrode,
metal water pipe, or metal building
structure that is in compliance with article 250 of NEC.
Chassis
Ground