Carrier Access 3200 Network Card User Manual


 
Adit 3200 - Release 1.6 13
Quick Start
Interface Connectors
Power
The Adit 3000 is powered by a limited -48 VDC Power source. The
following options are available:
z AC/DC Converter
z Battery Backup module
AC/DC Converter
An AC/DC Converter generates 48VDC from any worldwide AC power source.
To connect AC power:
1. Plug power connector from AC/DC converter into rear of Adit 3000.
2. Connect AC/DC converter to wall outlet.
3. A green light should appear on the Status LED on the front of the unit.
CAUTION! INCORRECT WIRING OF CORD MAY CAUSE EXTERNAL FUSE FAILURE.
WARNING! POSSIBLE SHOCK HAZARD EXISTS, PLEASE FOLLOW INSTRUCTIONS CAREFULLY.
To connect -48 VDC power:
1. Wire appropriate connector to open end of the DC Power cable.
Orange = -48 Black = Ground (+)
2. Plug the DC power connector in the -48 VDC input power connector.
3. Apply power to connector from -48 VDC power source.
4. A green light should appear on the Status LED on the front of the unit.
WARNING! EXTERNAL FUSE PROTECTION IS REQUIRED ON THE 48VDC INPUT WHEN
CONNECTED TO A DC POWER SOURCE NOT SUPPLIED BY CARRIER ACCESS.
Fuse Recommendations, or equivalent:
Battery Connection
The Adit 3000 Battery connection is provided for Battery Backup. See Adit 3104, 3200, 3300 and 3400
Battery Backup on page 8 for additional information.
Recommended Fuse AMP Rating
Littelfuse 48101.5 1.5 Amp
Bussman GMC-1.5A 1.5 Amp
PIN 10, ORANGE
PIN 5, BLACK