Casio handheld terminals Computer Hardware User Manual


 
20
2.2 DT-160IOE Bridge Satellite Cradle
Table 2.2
Item Specification Remark
Standard IrDA Ver. 1.1 compatible
Comm. method Half duplex
Synchronization Start/stop method
IrDA
Comm. speed 4 Mbps (maximum)
Standard USB Ver.1.1 compatible
Baud rate 12 Mbps (maximum)
USB
Connector
12
43
USB connector B type
1 VBus
2 – Data (D -)
3 + Data (D+)
4 GND
Comm. method Full duplex
Synchronization Start/stop method
Comm. speed 115.2 Kbps
RS-232C
Connector
SG ER SD RD CD
CI CS RS D
D-Sub 9-pin(Male)
1 VBus
2 – Data (D -)
3 + Data (D+)
4 GND
Comm. method Full duplex
Synchronization Start/stop method
Comm. speed 115.2 Kbps
Interface
RS-422
Connector
OUT
RDI-
RDI+
SDO-
SDO+
RSO-
RSO+
IN
RDO-
RDO+
SDI-
SDI+
RSI-
RSI+
IN
RDO-
RDO+
SDI-
SDI+
RSI-
RSI+
RJ-45 compatible (6 pins)
No. of LEDs 3
No. of display
colors
2 Red, green
Display Status LED
Display content System operation status
(“LINE”)
Communication status
(“DATA”)
Power status
(“POWER”)
Refer to Chapter
2.6 “Status
Indication with
LEDs”.
Dip switch 8 switches See page 24. Input
Detection switch for DT-X11
terminal
Push switch
Continue.