Casio handheld terminals Computer Hardware User Manual


 
35
5. Quality References
This chapter will describe about references of the DT-X11 and its dedicated options concerned with
environmental performance, compliance, mechanical and electric durability, etc.
5.1 Environmental Performances
5.1.1 DT-X11
Table 5.1
Item Specification Condition
Temperature
Operation -20 ºC to 50 ºC 0 to 40 ºC for charging
battery pack
DT-X11M30RC
DT-X11M30E
DT-X11M30U
Non-operation -20 ºC to 70 ºC
Operation -10 ºC to 50 ºC 0 to 40 ºC for charging
battery pack
DT-X11M10RC
DT-X11M10E
Non-operation -20 ºC to 60 ºC
Humidity
Operation 10 % to 80 %RH
Non-operation 5 % to 90 %RH
No condensation
Dust and water-splash proof
IP54 level, compliant with IEC60529 standard
Storage in carton box
Temperature -10 ºC to 50 ºC
Humidity 90 %RH (Maximum)
5.1.2 DT-160IOE/DT-169CHGE
Table 5.2
Item Specification Condition
Temperature
Operation 0 ºC to 40 ºC
Storage -10 ºC to 50 ºC
Humidity
Operation 30 % to 80 %RH
Storage 30 % to 90 %RH
No condensation
Storage in carton box
Temperature -10 ºC to 50 ºC
Humidity 30 % to 90 %RH No condensation