Cisco Systems H.323 Network Router User Manual


 
3-14
Cisco H.323 Signaling Interface User Guide
OL-4806-01 Rev. A14
Chapter 3 Provisioning the Cisco HSI
H.323 Stack Configuration
allowCallsWhenNonReg If this parameter is present, it
allows calls to proceed even
if gatekeeper registration has
not been done for the
PGW 2200.
NULL Not present Immediate
manualRegistration If this parameter is present,
the stack does not perform
automatic gatekeeper
registration procedures (it
waits to be driven by the
application).
NULL Not present Stop/Start
timeToLive The maximum time (in
seconds) that the registration
of the PGW 2200 with a
gatekeeper remains valid.
The stack reregisters
periodically.
INTEGER(1, 65535) 400 Immediate
rasPort* The number of the port
receiving all RAS
transactions for the current
endpoint. Set this parameter
to 0 to allow the software to
look for the available port.
INTEGER(0, 65535) 0 Start
compare15bitRasCrv If this parameter is present, it
causes the stack to ignore the
call reference value (CRV)
MSBit in RAS messages.
NULL Immediate
maxRetries* Maximum number of RAS
retransmissions.
INTEGER(1, 200) 3 Immediate
maxMulticastTTL Maximum number of
multicast time to live (TTL).
INTEGER(0, 200) 3 Start
preGrantedArqUse Choice of direct or routed. If
direct, the pregranted
Admission Request (ARQ)
feature is used for both direct
and routed calls. If routed,
the pregranted ARQ feature
is used only for routed calls.
If absent, the pregranted
ARQ is not used.
STRING direct Next Call
manualDiscovery.ipAddress The IP address of a known
gatekeeper with which an
endpoint might attempt to
register.
STRING 10.70.54.53 Start
Table 3-8 RAS Parameters (continued)
Parameter Name Description Type Example Update Type