Cisco Systems TEG-S2500i Switch User Manual


 
- 55 -
After input, user can choose the VLAN member in the Stacking Manager panel by clicking the
designated port. Color cycling from blue, yellow to black means that the port is set to untagged port,
tagged port or no member. When finishing , press " Apply" to submit.
It is always wise to remember that the Giga ports of each member switch are set to tagged port and
keeping at least one member port in the master switch.
The stacking switches interchange VLAN information through the Giga ports which are set to tagged
members by "Stacking Tag VLAN", so a new VLAN should keep its Giga ports as tagged ones. Since
the master switch holds all VLAN group information, the master switch should have the right to
access the new VLAN by adding at least one Giga port to it s tagged member. An exclusion of all
master switch ports leads to unmanageability on this VLAN, for master switch has no such VLAN in
its internal table.
Edit or Delete a VLAN
To edit an existing VLAN, just select the VLAN from the VLAN panel and modify the members