Cisco Systems uBR7246 Network Router User Manual


 
Configure the Downstream Cable Interface
VC-140
Voice, Video, and Home Applications Configuration Guide
Troubleshooting Tips
If you are having trouble:
Make sure the cable connections are not loose or disconnected.
Make sure the cable modem card is firmly seated in its Cisco uBR7246 chassis slot.
Make sure that you have entered the correct slot and port numbers when you typed the command.
Make sure you have calculated and entered the center frequency for your headend accurately.
Set the Downstream Symbol Rate
You need to set the megasymbols per second (Msps) rate for a downstream port on a cable modem
card. A symbol is the basic unit of modulation. QPSK encodes 2 bits per symbol, 16-QAM encodes
4 bits per symbol, 64-QAM encodes 6 bits per symbol, and 256-QAM encodes 8 bits per symbol.
The valid range for the downstream symbol rate is 0 to 6,000,000 Msps.
Caution The default downstream symbol rate is set to comply with MCNS specifications for Annex B
cable modem support at 5.056941 Msps with 64-QAM modulation and 5.36037 Msps with 256-QAM
modulation. This command should only be used to change the symbol rate to support Annex A cable modems
that are used outside North America.
To set the downstream symbol rate, use the following command in cable interface configuration
mode:
Validation Tips
To verify the downstream symbol rate, enter the show controllers cable command for the
downstream port that you have just configured:
router# show controllers cable 6/0 downstream
Cable6/0 Downstream is up
Frequency=96000000, Channel Width 6 MHz, 64-QAM, Symbol Rate 5.056941 Msps
FEC ITU-T J.83 Annex B, R/S Interleave I=32, J=4
Troubleshooting Tips
If you are having trouble:
Make sure the cable connections are not loose or disconnected.
Make sure the cable modem card is firmly seated in its Cisco uBR7246 chassis slot.
Make sure that you have entered the correct slot and port numbers when you typed the command.
Make sure you have selected the default if you are using Annex B cable modems.
Make sure that you have entered the correct symbol rate for Annex A specifications if you are
using Annex A cable modems. Do not enter the decimal point when entering the symbol rate.
Make sure the downstream carrier is active by entering the cable downstream if-output
command.
Command Purpose
cable downstream symbol-rate
number Set the downstream symbol rate for Annex A
(5.056944
Msps). Do not enter the decimal point in the
symbol rate.