Compaq DL585 G2 Server User Manual


 
Serviceability
ServiceabilityServiceability
Serviceability
System Insight Display - precisely depicts all major subsystems of the server (PCI I/O, Memory,
CPU, Redundant Cooling, Interlock, Thermtrip) and gives instant visual indication of fault status.
Located on top front of server, beneath lid.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Two ejectable, slimline Media Bay media drives (DVD/CD-RW standard with support for
optional floppy or optical drives) are removable without the use of tools
Front accessible processors and memory
PCI Card Guides locks full length PCI cards in place during transit
Six individually removable fans connect without cables to the system board
Tool-less removal of system board
Quick Deploy Rails
Tool-less design "snap in" rail
Security
SecuritySecurity
Security
Power-on password
Keyboard password
Diskette drive control enable/disable
Diskette boot control enable/disable
External USB port enable/disable
Network Server Mode
Serial interface control
Administrator's password
Removable Diskette drive (optional)
Removable optical drive
Power Supply
Power SupplyPower Supply
Power Supply
910W (low line), 1300W (high line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L).
NOTE:
NOTE: NOTE:
NOTE:
One Hot Plug Power Supply ships standard with 2.0GHz and 2.2GHz models (optional
Redundant Hot Plug Power Supply Option Kit).
NOTE:
NOTE: NOTE:
NOTE:
Two Hot Plug Power Supplies ship standard with 2.4GHz, 2.6GHz, 2.8GHz, and 3.0GHz
models.
UPS and PDU Power
UPS and PDU PowerUPS and PDU Power
UPS and PDU Power
Cord Matrix
Cord MatrixCord Matrix
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications
for UPS and PDU units:
http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html
.
Server Power Cords
Server Power CordsServer Power Cords
Server Power Cords
IEC320-C14 to IEC320-C19 Jumper Cord
NOTE:
NOTE:NOTE:
NOTE:
The HP ProLiant DL585 G2 servers ship standard worldwide with a 6-foot IEC 320-C14 to
IEC320-C19 jumper cord. If you require a local power cord, please check the Power Specifications
below for the appropriate country-specific power cord, or consult the Power Cord Matrix:
http://www.hp.com/go/powercordmatrix
.
System Fans
System FansSystem Fans
System Fans
Standard
6 Hot plug, redundant fans (individually removable)
Maximum
6 Hot plug, redundant fans (individually removable)
QuickSpecs
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
Standard Features
DA - 12575 Canada — Version 37 — May 28, 2008