Compaq DL585 G2 Server User Manual


 
Part number
Part numberPart number
Part number
348114-001
Operational Input Voltage Range
Operational Input Voltage RangeOperational Input Voltage Range
Operational Input Voltage Range
(Vrms)
90 to 264
Frequency Range
Frequency RangeFrequency Range
Frequency Range
(Nominal) (Hz)
47 to 63 (50/60)
Nominal Input Voltage
Nominal Input VoltageNominal Input Voltage
Nominal Input Voltage
(Vrms)
100
100100
100 115
115115
115 208
208208
208 220
220220
220 230
230230
230 240
240240
240
Max Rated Output Wattage Rating
910 910
1300 1300 1300 1300
Nominal Input Current (A rms)
11.9 10.2
7.7 7.3 6.9 6.6
Max Rated Input Wattage Rating (Watts)
1163 1148 1566 1566 1548 1548
Max. Rated VA (Volt-Amp)
1186 1172 1598 1598 1579 1579
Efficiency (%)
80 81 83 83 84 84
Power Factor
0.98 0.98
Leakage Current (mA)
0.43 0.50 0.90 0.96 1.00 1.04
Max. Inrush Current (A peak)
100 100 100 100 100 100
Max. Inrush Current duration (mS)
10
NOTE:
NOTE: NOTE:
NOTE:
– To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool
located at url:
http://h30099.www3.hp.com/configurator/powercalcs.asp
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL585 G2
Click on: "Power Calculator" link. (You may need to scroll down to see it)
There are certain Dual-core, lowline, max configurations that are not supported. All highline configurations are supported.
Consult the Power Calculator to determine if your lowline configuration is supported.
Standard Rack Model
Standard Rack ModelStandard Rack Model
Standard Rack Model
Power Cords / Jumper
Power Cords / JumperPower Cords / Jumper
Power Cords / Jumper
Cords
CordsCords
Cords
Description
DescriptionDescription
Description
IEC320-C14 to IEC320-C19 Jumper Cord
Optional Country Power
Optional Country PowerOptional Country Power
Optional Country Power
Cords and Jumper Cords
Cords and Jumper CordsCords and Jumper Cords
Cords and Jumper Cords
Description
DescriptionDescription
Description
Option Kit Part
Option Kit PartOption Kit Part
Option Kit Part
Number
NumberNumber
Number
Nema 5-15P to IEC320-C19
235603-001
Nema 6-20P to IEC320-C19
235604-001
Nema L6-20P to IEC320-C19, 20A, 250V
340653-001
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 6 ft/2.0m)
313227-B21
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 8 ft/2.5m)
291034-B21
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 10 ft/3.0m)
310927-B21
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 12ft/3.7m)
313228-B21
IEC320-C19 to IEC320-C20 Jumper (16A, IEC, 8ft/2.5m)
295633-B22
QuickSpecs
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
Power Specifications
DA - 12575 Canada — Version 37 — May 28, 2008
Page 40