DIGITAL-LOGIC AG MSEBX800/900 Detailed Manual V1.0
17
Operating Temperature Specification:
MIL-810-501
MIL-810-502
Extended temperature range:
SM800PCX (500MHz)
-40°C to +70°C
Security
e1 Not planned
UL Not planned
ETS 301 Not planned
CE/SEV Yes
Safety AR385-16
If all signals are externally filtered and assembled into an enclosed metallic case!
EMI / EMC Tests Specification
EMC emission EN61000-6-2:2001
Conducted disturbance EN55022 Class B
Radiated disturbance EN55022 Class B
EMC immunity EN61000-6-2
Electrostatic discharge (ESD) EN61000-4-2
Voltage = 4kV contact / 8kV air, Criteria A
Radiated RF-Field EN61000-4-3
Level = 10V/m, Criteria A
Electrical fast transients (Burst) EN61000-4-4
Grade 2: DC-Power lines = 1000V (5/50ns)
Grade 2: AC-Power lines = 2000V (5/50ns)
Grade 2: Signal lines = 500V (5/50ns)
Criteria B
Surge EN61000-4-5
Grade 2: DC-Power lines = 1kV, (1.2/50us)
Grade 2: AC-Power lines = 2kV, (1.2/50us)
Criteria B
Conducted disturbances EN61000-4-6
Voltage = 10V coupled by case, Criteria A
All information is subject to change without notice.