22 Chapter 6 - Basic Configuration Guide
CV: Use the DECnet Routing Dialog Box (under Global/DECnet
Routing) and the DECnet: Ethernet Dialog Box.
TB: Use configure and set the Enabled, Area, and Node keywords in
the DECnet Global section.
v Note: Setting DECnet on for any port with the command line also
sets DECnet on globally. In CompatiView you must set a global
parameter and a port-specific parameter.
Suggested for DECnet
Setting the parameters above should be adequate for most installations.
WAN Interface Configuration
This section covers the settings required for PPP (point-to-point)
protocol operation of the RISC Router 3500R WAN interfaces. In
general, the parameters listed here should be set for each WAN inter-
face on which you plan to use PPP. Note that some WAN interfaces can
be running PPP while others are running Frame Relay.
The V.35 interface can only be run synchronously, at rates up to 2 Mbps
per second.
Physical Communications Settings
You may need to set the baud rate, sync/async operation, and other
physical communications parameters for the WAN interface. These
parameters will depend on the line communications device you are
using.
CV: Use the Physical Configuration: WAN 0 Dialog Box.
TB: Use configure and the V.35 Interface WAN 0 (and/or other port
numbers you wish to configure) section.