Contec 4(FIT)GY 1 Computer Hardware User Manual


 
Ver.1.00
DIO-4/4(FIT)GY 2
CAUTION
When connecting one of the modules to a controller module,
the internal current consumption should be taken into
account. If the total current exceeds the capacity of the
power supply unit, the integrity of the operation cannot be
guaranteed. For further details, please see the Controller
Module manual.
Stack Connector
Control Circuit
Device ID
Interface Connector IN00 - IN03 Interface Connector OUT00 - OUT03
Opto-Coupler
Opto-Coupler &
Transistor
Tri-State
Buffer
Output Data
Latch
(1.2) (1.2)
94
25.23.5 64.7 4.0
[mm]
14
31.5
14.0
35.0
45.0
DI-8
Device
ID
X
COM1
COM0
NC
NC
0
1
2
3
4
5
6
7
4567
X
0123
0
4
0
4
6
2
This product can be connected to a variety of controllers.
Supported controllers
Microcontroller Unit : CPU-SBxx(FIT)GY
I/O Controller Module : CPU-CAxx(FIT)GY
Monitoring & Control Server Unit : SVR-MMF2(FIT)
Monitoring & Control Server Unit : SVR-MMF(FIT)GY
Check each controller to which the module can be connected
as well as the method of controlling the module when
connected to that controller.
Connections to controllers
O: Permitted
×: Not permitted
C
P
U
-
S
B
x
x
(
F
I
T
)
G
Y
C
P
U
-
C
A
x
x
(
F
I
T
)
G
Y
S
V
R
-
M
M
F
2(
F
I
T
)
S
V
R
-
M
M
F
(
F
I
T
)
G
Y
DIO-4/4(FIT)GY ΟΟΟΟ
DI-8(FIT)GY ΟΟΟΟ
DO-8(FIT)GY ΟΟΟΟ
Device ID setting range 0 - 7 0 - 7 0 - 7 0 - 7
Control method by controller connected
C
P
U
-
S
B
x
x
(
F
I
T
)
G
Y
C
P
U
-
C
A
x
x
(
F
I
T
)
G
Y
S
V
R
-
M
M
F
2(
F
I
T
)
S
V
R
-
M
M
F
(
F
I
T
)
G
Y
Control using the I/O address map Ο
Control using the memory address map
Ο
FIT Protocol
Ο
API-CAP(W32)
Ο
API-SBP(W32)
Ο
Control over the web
(as set from within the browser)
ΟΟ
Control via the Windows driver *
* The API-SBP(W32) is included in the development kit [DTK-SBxx(FIT)GY]; the other
drivers are bundled with each controller.
Control using the I/O address map
When connected to the CPU-SBxx(FIT)GY, the module can
receive I/O instructions directly from the controller module.
Control using the memory address map
When connected to the CPU-CAxx(FIT)GY, the module can be
accessed from the host computer over the network. The
module is assigned with its device ID in the memory managed
by the controller module. The application running on the host
computer controls the module by reading/writing the memory
managed by the controller module.
Control via the Windows driver
For the functions and settings available when using the
Windows driver, refer to the reference manual and online help
for each module.
Control over the web
You can monitor collected data and manage the log over the
web. You can use your familiar browser to easily make
various settings. For details, refer to the reference manual for
the SVR-MMF2(FIT), SVR-MMF(FIT)GY.
Block Diagram
Physical Dimensions
Functions and control method by
controller connected