Connector Pin Assignment
CN1
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Digit al Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
+5V DC from PC
Simultaneous Hold Output
Analog Output
Analog Input 7 [
-
]
Analog Input 7 [+]
Analog Input 6 [
-
]
Analog Input 6 [+]
Analog Input 5 [
-
]
Analog Input 5 [+]
Analog Input 4 [
-
]
Analog Input 4 [+]
Analog Input 3 [
-
]
Analog Input 3 [+]
Analog Input 2 [
-
]
Analog Input 2 [+]
Analog Input 1 [
-
]
Analog Input 1 [+]
Analog Input 0 [
-
]
Analog Input 0 [+]
CN1
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Digital Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
Analog Ground
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
+5V DC from PC
Simultaneous Hold Output
Analog Output
Analog Input 15
Analog Input 7
Analog Input 14
Analog Input 6
Analog Input 13
Analog Input 5
Analog Input 12
Analog Input 4
Analog Input 11
Analog Input 3
Analog Input 10
Analog Input 2
Analog Input 9
Analog Input 1
Analog Input 8
Analog Input 0
< Single-Ended Input > < Differential Input >
Analog Input 0
to Analog Input 15
Analog input signals in single-ended input mode.
The numbers correspond to channel numbers.
Analog Input 0[+]
to Analog Input 15[+]
Analog input signals in differential input mode.
The numbers correspond to channel numbers.
Analog Input 0[-]
to Analog Input 15[-]
Analog input signals in differential input mode.
The numbers correspond to channel numbers.
Analog Output Analog output signal
Analog Ground Analog ground common to analog I/O signals.
Simultaneous Hold
Output
Control signal for simultaneous sampling unit ATSS-16 available as an
option.
+5V DC from PC Supplies 3 amperes of current at +5 volts.
Digital Ground
Digital ground common to "Simultaneous Hold Output" and "+5V DC from
PC".
Notes!
- Please connect each output and power supply output neither with analog ground nor digital ground too hastily.
- Moreover, please do not connect output and output. It becomes the cause of failure.
CN2
A8
A7
A6
A5
A4
A3
A2
A1
B8
B7
B6
B5
B4
B3
B2
B1
+5V DC from PC
Sampling Clock Output
External Stop Trigger I nput
Digital Input 3 / INT Trigger
Digital Input 1 / CNT Gate
Digital Ground
Digital Output 2
Digital Output 0
N. C.
Digital Ground
External Sampling Clock Input
External St art Trigger Input
Digital I nput 2 / CNT Clock
Digital Input 0
Digital Output 3 / CNT Output
Digital Output 1
Digital Input 0 Digital input signal.
Digital Input 1
/CNT Gate
Digital input signal.
Also serving as the counter gate control input signal.
Digital Input 2
/CNT Clock
Digital input signal.
Also serving as the clock input signal
Digital Input 3
/INT Trigger
Digital input signal.
Also serving as the interrupt input signal.
Digital Out 0
to Digital Out 2
Digital output signal.
Digital Out 3
to CNT Output
Digital output signal.
Capable of being jumper-switched to serve as the counter output
signal.
External Start Trigger Input External trigger input signal for sampling start conditions
External Stop Trigger Input External trigger input signal for sampling stop conditions
External Sampling Clock
Input
External sampling clock input signal
Sampling Clock Output Sampling clock output signal
+5V DC from PC Supplies 1 ampere of current at +5 volts.
Digital Ground Digital ground common to the signals and “+5V DC from PC”.
N.C. No connection to this pin.
Notes!
- Please connect each output and power supply output neither with analog ground nor digital ground too hastily.
- Moreover, please do not connect output and output. It becomes the cause of failure.