Switching Characteristics
Over the Operating Range
[22, 23]
Parameter
Description
–133 –100
Unit
Min. Max. Min. Max.
t
POWER
V
DD
(Typical) to the first Access
[18]
11ms
Clock
t
CYC
Clock Cycle Time 7.5 10 ns
t
CH
Clock HIGH 2.5 3.0 ns
t
CL
Clock LOW 2.5 3.0 ns
Output Times
t
CDV
Data Output Valid After CLK Rise 6.5 8.5 ns
t
DOH
Data Output Hold After CLK Rise 2.5 2.5 ns
t
CLZ
Clock to Low-Z
[19, 20, 21]
2.5 2.5 ns
t
CHZ
Clock to High-Z
[19, 20, 21]
3.8 0 4.5 ns
t
OEV
OE LOW to Output Valid 3.0 3.8 ns
t
OELZ
OE LOW to Output Low-Z
[19, 20, 21]
00ns
t
OEHZ
OE HIGH to Output High-Z
[19, 20, 21]
3.0 4.0 ns
Setup Times
t
AS
Address Setup Before CLK Rise 1.5 1.5 ns
t
ADS
ADSP, ADSC Setup Before CLK Rise 1.5 1.5 ns
t
ADVS
ADV Setup Before CLK Rise 1.5 1.5 ns
t
WES
GW, BWE, BW
X
Setup Before CLK Rise 1.5 1.5 ns
t
DS
Data Input Setup Before CLK Rise 1.5 1.5 ns
t
CES
Chip Enable Setup 1.5 1.5 ns
Hold Times
t
AH
Address Hold After CLK Rise 0.5 0.5 ns
t
ADH
ADSP, ADSC Hold After CLK Rise 0.5 0.5 ns
t
WEH
GW, BWE, BW
X
Hold After CLK Rise 0.5 0.5 ns
t
ADVH
ADV Hold After CLK Rise 0.5 0.5 ns
t
DH
Data Input Hold After CLK Rise 0.5 0.5 ns
t
CEH
Chip Enable Hold After CLK Rise 0.5 0.5 ns
Notes
18.This part has a voltage regulator internally; t
POWER
is the time that the power must be supplied above V
DD
(minimum) initially, before a read or write operation can be
initiated.
19.t
CHZ
, t
CLZ
,t
OELZ
, and t
OEHZ
are specified with AC test conditions shown in part (b) of “AC Test Loads and Waveforms” on page 20. Transition is measured ± 200 mV
from steady-state voltage.
20.At any given voltage and temperature, t
OEHZ
is less than t
OELZ
and t
CHZ
is less than t
CLZ
to eliminate bus contention between SRAMs when sharing the same data
bus. These specifications do not imply a bus contention condition, but reflect parameters guaranteed over worst case user conditions. Device is designed to achieve
High-Z prior to Low-Z under the same system conditions.
21.This parameter is sampled and not 100% tested.
22.Timing reference level is 1.5V when V
DDQ
= 3.3V and is 1.25V when V
DDQ
= 2.5V.
23.Test conditions shown in (a) of AC Test Loads unless otherwise noted.
[+] Feedback