Datalogic Scanning 1000I Scanner User Manual


 
Code 39
Product Reference Guide
5-27
Code 39 Length 1, Length 2 Programming Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent-
ing the length in decimal notation.
4. Scan the START/END bar code.
Quiet Zones
This feature enables/disables the requirement that quiet zones must be present for Code 39 bar
codes.
NOTE
For Code 39 bar codes, all check, data and full ASCII
shift characters are included in the length calculations.
Start/Stop characters are not included.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 050
START / END
PROGRAMMING BARCODES
Don’t require Quiet Zones
DEFAULT
Require Quiet Zones