Datalogic Scanning 8500 Scanner User Manual


 
Product Reference Guide 6-235
Codabar Maximum Label Length
This feature specifies the maximum allowable length of a Codabar label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET CODABAR MAXIMUM LABEL
LENGTH below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired maximum label length. The selectable range
for this option is 03 to 50. Pad all single digit numbers with a
leading zero to yield a two-digit entry (03-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODABAR MAXIMUM LABEL LENGTH
NOTE
Length in this case includes start, stop or check and data characters, but
does not include full ASCII shift characters. This feature applies when
Codabar Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label
length.